| Solar Panels | Solar Regulators | Inverters | Solar Power Sys | UPS Inverter |
Solar Charge Controllers- Solar Charge Controllers below 25Amp
BLETON 15 Amp MPPT Solar Charge Controller
Electronic Protections:
-
Overcharge Protection
-
Over discharge Protection
-
Battery Reverse Current Protection
-
Overloading Protection
-
Short Circuit Protection
-
Battery Reverse Polarity Connection Protection
Comparison between a MPPT charge controller and a Normal controller:
Normal
Solar Charge Controller:
Solar Panel works at point A state, the
solar panel working voltage is a little
higher than battery voltage.
Charge Voltage: UA=13.2V
Charge Current:: IA=9.8A
Charge Power: PA=13.2*9.8=129.36w
Area in drawing: 1 + 3
MPPT Solar
Charge Controller:
Solar Panel works at point B state, the
solar panel working voltage much higher
than battery voltage.
Charge Voltage: UB=18.4V
Charge Current:: IB=9.3A
Charge Power: PB=18.4*9.3=171.12w
Area in drawing: 1 + 2

Comparison:
The power B is more than power A.. ΔP/
PA =(PB— PA)/ PA=32..3%
As a result the effective power increase
rate is 30%.
Technical Data of BLETON MPPT Solar
Charge Controller:
Model
BMPT2415
BMPT2420
BMPT2430
Max. load current
15A
20A
30A
Max. Charge current
15A
20A
30A
Voltage Drop
<240mv
<300mv
<300mv
Rated Voltage
12V or 24 V
High Voltage Disconnection
13.7V/27.4V/54.8V (25℃),adjustable
Low Voltage Disconnection
10.5V/21V/42V,adjustable
Low Voltage Reconnection
12.6V /25.2V/50.4V
Temperature Compensation
-3mv/C°/cell
Max. own consumption
30mA
Biggest connection terminal
10mm²
Size
188×93×55mm
/
188×118×55mm
Weight
0.55kg / 0.65kg
20 Amp MPPT BLETON Solar Charge Regulator
Electronic Protections:
-
Overcharge Protection
-
Over discharge Protection
-
Battery Reverse Current Protection
-
Overloading Protection
-
Short Circuit Protection
-
Battery Reverse Polarity Connection Protection
BLETON 25 Amp MPPT Solar Charge Controller
Electronic Protections:
-
Overcharge Protection
-
Over discharge Protection
-
Battery Reverse Current Protection
-
Overloading Protection
-
Short Circuit Protection
-
Battery Reverse Polarity Connection Protection
|
Model |
BMPT4815 |
BMPT4820 |
BMPT4830 |
|
Max. load current |
15A |
20A |
30A |
|
Max. Charge current |
15A |
20A |
30A |
|
Voltage Drop |
<240mv |
<300mv |
<300mv |
|
Rated Voltage |
12V,24V or 48V |
||
|
High Voltage Disconnection |
13.7V/27.4V/54.8V (25℃),adjustable |
||
|
Low Voltage Disconnection |
10.5V/21V/42V,adjustable |
||
|
Low Voltage Reconnection |
12.6V /25.2V/50.4V |
||
|
Temperature Compensation |
-3mv/C°/cell |
||
|
Max. own consumption |
30mA |
||
|
Biggest connection terminal |
10mm² |
||
|
Size |
188×93×55mm / 188×118×55mm |
||
|
Weight |
0.55kg / 0.65kg |
||
BLETON 12 Amp PWM Solar Charge Controller
![]() |
Features:
|
Electronic Protections:
-
Overloading protection
-
Short circuit protection
-
Reverse current protection
-
Reverse polarity protection
-
Lightning protection
-
Overcharge protection
-
Over discharge protection
Technical Data of 12Amp Solar Charge Controller:
| Model | BR2406 | BR2412 |
|---|---|---|
| Max. load current | =6A | =12A |
| Voltage Drop | <140mv | <210mv |
| Rated Voltage | 12/24 V auto | |
| High Voltage Disconnection | 13.7V -27.4V | |
| Low Voltage Disconnection | 10.5V -21.0V | |
| Low Voltage Reconnection | 12.6V -25.2V | |
| Temperature Compensation | -3mv/C°/cell | |
| Max. own consumption | =20mA | |
| Biggest connection terminal | 2.5mm² | |
| Size | 102x45x107mm | |